L&T DN0-125D MCCB 125A (100-125A) 3 Pole 36kA Thermal Magnetic | CM90680OOLOOG (image for illustration purpose only)
L&T DN0-125D MCCB 125A (100-125A) 3 Pole 36kA Thermal Magnetic | CM90680OOLOOG Original price was: ₹13,400.00.Current price is: ₹5,360.00.
+ GST ₹964.80
Back to products
L&T DN0-100C MCCB 20A (16-20A) 3 Pole 25kA Thermal Magnetic | CM91612OOCOOG (image for illustration purpose only)
L&T DN0-100C MCCB 20A (16-20A) 3 Pole 25kA Thermal Magnetic | CM91612OOCOOG Original price was: ₹12,100.00.Current price is: ₹4,840.00.
+ GST ₹871.20

L&T DN0-125D MCCB 125A (100-125A) 4 Pole 36kA Thermal Magnetic | CM90681OOLOOG

₹8,354.40 Incl. of Taxes -60%Original price was: ₹17700.00.Current price is: ₹7080.00.+ GST ₹1,274.40 (18%)

+ GST (18%): ₹1274.40
Total payable: ₹8354.40

Product image is for illustration purpose only – the photo shows a different rating of the same dsine family.
L&T / Lauritz Knudsen dsine DN0-125D MCCB, catalog no. CM90681OOLOOG
125A (100-125A), 4 Pole, 36kA @ 415V AC breaking capacity (Ics = 50% of Icu)
Adjustable thermal 0.8-1.0 x In, fixed magnetic
GST invoice on every order | Same-day dispatch in Bengaluru for orders before 4 PM
Bulk and project rates on WhatsApp: +91 78160 62494

SKU: CM90681OOLOOG Categories: , Tag:
Description

Note: the product photo is for illustration purpose only – it shows a different rating of the same dsine family. The unit supplied is exactly the catalog number and rating on this page.

Looking for the L&T DN0-125D MCCB 125A 4 Pole? This is the genuine Lauritz Knudsen (formerly L&T Switchgear) dsine DN series moulded case circuit breaker, catalog number CM90681OOLOOG, made for feeder, incomer and sub-distribution protection in commercial buildings, industries and OEM panels. We stock it at our Chamrajpet shop in Bengaluru with a GST invoice on every order, same-day dispatch for orders placed before 4 PM (Monday to Saturday), and delivery across all of Bengaluru including outskirts. Free store pickup is available. For project and bulk rates, WhatsApp us on +91 78160 62494.

Breaking capacity is 36 kA at 415V AC (Ics = 50% of Icu). The dsine DN range gives you a thermal-magnetic release with an adjustable thermal (overload) setting from 0.8 to 1.0 times In – this unit covers 125A (100-125A) – and a fixed magnetic short-circuit trip at 9 times In (1125A on this 125A unit). That adjustability lets you trim the protection to the actual load and cable size during commissioning.

Spreader terminals are not included with this catalog number – if your panel needs them for cable termination, add the matching DN0-125 4 pole spreader link set and, for panel-door operation, the direct or extended rotary handle from the Frequently Bought Together section below. One set covers one MCCB. Phase barriers are supplied with the unit.

Practical panel-builder details: no load-line bias, so supply and load can connect to either side; clear ON / TRIP / OFF indication; suitable for isolation; conforms to IS/IEC 60947-2.

Note on branding: L&T Switchgear is now Lauritz Knudsen Electrical & Automation (renamed in May 2024). Depending on stock, the unit may carry either the L&T or Lauritz Knudsen name. The catalog number, specifications and quality are identical.

📋 Technical Specifications

ParameterValue
BrandL&T / Lauritz Knudsen
Part Number / SKUCM90681OOLOOG
CategoryMCCB (Moulded Case Circuit Breaker)
Seriesdsine DN0-125D
Current Rating (In)125 A (adjustable range 125A (100-125A))
Poles4 Pole
Breaking Capacity (Icu)36 kA @ 415V AC (Icu @ 415V AC)
Service Breaking Capacity (Ics)50% of Icu
Release TypeThermal-Magnetic (adjustable thermal, fixed magnetic)
Thermal (Overload) SettingAdjustable 0.8 – 1.0 x In (this unit settable 125A (100-125A))
Magnetic (Short Circuit) SettingFixed magnetic, 9 x In (1125 A for this 125A unit)
Rated Operational Voltage (Ue)600V AC, 50/60 Hz
Rated Insulation Voltage (Ui)800 V
Impulse Withstand Voltage (Uimp)8 kV
Utilization CategoryA
StandardIS/IEC 60947-2
Making Capacity (Icm)75.6 kA
Mechanical / Electrical Life40,000 / 8,000 operations
Dimensions (W x D x H)100 x 60 x 130 mm
Weight1 kg
IP Rating / IsolationIP40 (front), suitable for isolation

⚡ Key Features

  • Genuine L&T / Lauritz Knudsen dsine DN0-125D MCCB – catalog no. CM90681OOLOOG
  • 125A, 4 Pole, 36 kA breaking capacity at 415V AC (Ics = 50% of Icu)
  • Adjustable thermal release 0.8 – 1.0 x In; fixed magnetic trip
  • Phase barriers included; spreader terminals and rotary handles available separately below
  • No load-line bias – connect supply and load on either side
  • Clear ON / TRIP / OFF indication; suitable for isolation
  • GST invoice on every order; same-day dispatch in Bengaluru for orders before 4 PM

📄 Official Catalogue / Datasheet

Download the official L&T / Lauritz Knudsen dsine DN MCCB catalogue (covers DN0-125D technical data, trip curves, accessories and dimensions): dsine DN MCCB Catalogue (PDF, official)

❓ Frequently Asked Questions

Where can I use a 36 kA MCCB like the DN0-125D?

Use it where the prospective short-circuit level at the installation point is 36 kA or less – typically incomers and feeders in commercial and industrial distribution boards. Your panel designer or electrician works this out from the upstream transformer rating. The dsine DN range covers 25 kA, 36 kA and 50 kA variants – if you need a different fault level, ask us on WhatsApp and we will point you to the right catalog number.

Can I adjust the trip settings on this MCCB?

Partly – the DN0-125D has an adjustable thermal (overload) dial from 0.8 to 1.0 times In, so this 125A unit can be set anywhere in the 125A (100-125A) range. The magnetic short-circuit trip is fixed at 9 times the rated current (1125A on this unit). If you need fully adjustable electronic settings, look at the DN range with MTX microprocessor releases.

Are spreader terminals included with this MCCB?

No – CM90681OOLOOG is the without-spreader variant, which keeps the price lower. If your panel needs spreader terminals for 4 pole cable termination, add the matching DN0-125 4 pole spreader link set from the Frequently Bought Together section below – one set covers one MCCB.

How fast can you deliver in Bengaluru?

Orders placed before 4 PM, Monday to Saturday, are dispatched the same day. We deliver across all of Bengaluru including outskirts like Sarjapur, Anekal and the airport side. Delivery charges are confirmed with you before dispatch. You can also pick up free from our Chamrajpet shop.

Do I get a GST invoice and what are the payment options?

Every order comes with a GST invoice suitable for ITC claims and project billing. Payment is prepaid through PhonePe – UPI, cards and netbanking are all accepted. For bulk quantities and project rates, WhatsApp us on +91 78160 62494.

Additional information
BrandL&T
SeriesDN0-125D
Ampere125A
Poles4 Pole
Breaking Capacity36 kA
Trip UnitThermal Magnetic
Voltage Rating415V AC