L&T DY250U1 MCCB 200-250A 4 Pole CM98196OOPO - image for illustration purpose only (photo shows 160A unit)
L&T DY250U1 MCCB 200-250A 4 Pole 415V 10kA Thermal Magnetic | CM98196OOPO Original price was: ₹17,900.00.Current price is: ₹11,277.00.
+ GST ₹2029.86
Back to products
L&T DY125U MCCB 80A 2 Pole EM90812OOJO - image for illustration purpose only
L&T DY125U MCCB 80A 2 Pole 240V 25kA Thermal Magnetic | EM90812OOJO Original price was: ₹2,560.00.Current price is: ₹1,612.80.
+ GST ₹290.30

L&T DY125U MCCB 80A 2 Pole 240V 25kA Thermal Magnetic | EM90982OOJO

₹2,096.39 Incl. of Taxes -37%Original price was: ₹2820.00.Current price is: ₹1776.60.+ GST ₹319.79 (18%)

+ GST (18%): ₹319.79
Total payable: ₹2096.39

Product image is for illustration purpose only – the photo shows a different rating of the same model.
L&T / Lauritz Knudsen DY125U MCCB, catalog no. EM90982OOJO
80A, 2 Pole, 240V AC, 25kA breaking capacity (Icu = Ics)
Fixed thermal-magnetic release – spreader terminals included
GST invoice on every order | Same-day dispatch in Bengaluru for orders before 4 PM
Bulk and project rates on WhatsApp: +91 78160 62494

SKU: EM90982OOJO Categories: , Tag:
Description

Note: the product photo is for illustration purpose only – it shows a different rating of the same model. The unit supplied is exactly the catalog number and rating on this page.

Looking for the L&T DY125U MCCB 80A 2 Pole? This is the genuine Lauritz Knudsen (formerly L&T Switchgear) DY series moulded case circuit breaker, catalog number EM90982OOJO, made for feeder and sub-distribution protection in shops, small industries, commercial buildings and OEM panels. We stock it at our Chamrajpet shop in Bengaluru with a GST invoice on every order, same-day dispatch for orders placed before 4 PM (Monday to Saturday), and delivery across all of Bengaluru including outskirts. Free store pickup is available. For project and bulk rates, WhatsApp us on +91 78160 62494.

The DY125U 2 Pole is built in the 3 pole frame size (75 mm width), so it matches the full DY125U accessory range. This catalog number EM90982OOJO is the variant spreader terminals included. Spreader terminals and phase barriers come in the box, so terminating aluminium or copper cables up to 50 mm² is straightforward. The fixed thermal-magnetic release needs no settings or commissioning: overload protection is thermal and short-circuit protection trips magnetically at 10 times the rated current.

Breaking capacity is 25 kA at 240V AC (Ics = 100% of Icu) – the 2 pole DY125U is rated for 240V AC systems, with 10 kA at 250V DC when both poles are wired in series. If your installation is a 415V three-phase board, use the 3 pole or 4 pole DY125U instead, and where the fault level exceeds these values, look at the DU range (18-50 kA) or the dsine DN range – we stock those too.

Practical panel-builder details: no load-line bias, so supply and load can connect to either side; clear ON / TRIP / OFF indication; suitable for isolation; conforms to IS/IEC 60947-2, IEC 60947-2 and EN 60947-2. The whole DY125U family covers 16A to 125A in 2, 3 and 4 pole versions.

Note on branding: L&T Switchgear is now Lauritz Knudsen Electrical & Automation (renamed in May 2024). Depending on stock, the unit may carry either the L&T or Lauritz Knudsen name. The catalog number, specifications and quality are identical.

📋 Technical Specifications

ParameterValue
BrandL&T / Lauritz Knudsen
Part Number / SKUEM90982OOJO
CategoryMCCB (Moulded Case Circuit Breaker)
SeriesDY125U
Current Rating (In)80 A
Poles2 Pole (in 3 Pole frame size)
Breaking Capacity (Icu)25 kA (Icu = Ics) (@ 240V AC; 10 kA @ 250V DC (2P in series))
Service Breaking Capacity (Ics)100% of Icu
Release TypeThermal-Magnetic (fixed settings)
Thermal (Overload) SettingFixed
Magnetic (Short Circuit) SettingFixed, 10 x In (800 A for this 80A unit)
Rated Operational Voltage (Ue)240V AC, 50/60 Hz
Rated Insulation Voltage (Ui)800 V
Impulse Withstand Voltage (Uimp)8 kV
Utilization CategoryA
StandardIS/IEC 60947-2, IEC 60947-2, EN 60947-2
Terminal Capacity50 mm² cable with lug (link ≤17 mm); spreader terminals included with this variant
Mechanical / Electrical Life30,000 / 8,000 operations
Dimensions (W x D x H)75 x 60 x 130 mm
Weight0.60 kg
IP Rating / IsolationIP40 (front), suitable for isolation

⚡ Key Features

  • Genuine L&T / Lauritz Knudsen DY125U economy-range MCCB – catalog no. EM90982OOJO
  • 80A, 2 Pole (3 pole frame size), 240V AC, 25 kA breaking capacity (Icu = Ics)
  • Fixed thermal-magnetic release – no settings needed, works out of the box
  • Spreader terminals and phase barriers included with this variant
  • No load-line bias – connect supply and load on either side
  • Clear ON / TRIP / OFF indication; suitable for isolation
  • GST invoice on every order; same-day dispatch in Bengaluru for orders before 4 PM

📄 Official Catalogue / Datasheet

Download the official L&T / Lauritz Knudsen DU/DY MCCB catalogue (covers DY125U technical data, trip curves, accessories and dimensions): DU/DY MCCB Catalogue (PDF, official)

❓ Frequently Asked Questions

Where can I use a 25 kA 2 pole MCCB like the DY125U?

The 2 pole DY125U is rated 25 kA at 240V AC, so it suits 240V single-phase feeders and distribution boards where the prospective fault level is 25 kA or less. For 415V three-phase boards, pick the 3 pole or 4 pole version. Your panel designer or electrician confirms the fault level from the upstream transformer rating.

Can I adjust the trip settings on this MCCB?

No – the DY125U has a fixed thermal-magnetic release. Overload protection is thermal and short-circuit protection trips magnetically at 10 times the rated current (800A on this 80A unit). That makes it simple and reliable with nothing to commission. If you need adjustable settings, look at the DU range or the dsine DN range with MTX microprocessor releases.

Are spreader terminals included with this MCCB?

Yes. This catalog number EM90982OOJO is the with-spreader-terminals variant – spreaders and phase barriers come in the box, which makes terminating up to 50 mm2 cable easy.

How fast can you deliver in Bengaluru?

Orders placed before 4 PM, Monday to Saturday, are dispatched the same day. We deliver across all of Bengaluru including outskirts like Sarjapur, Anekal and the airport side. Delivery charges are confirmed with you before dispatch. You can also pick up free from our Chamrajpet shop.

Do I get a GST invoice and what are the payment options?

Every order comes with a GST invoice suitable for ITC claims and project billing. Payment is prepaid through PhonePe – UPI, cards and netbanking are all accepted. For bulk quantities and project rates, WhatsApp us on +91 78160 62494.

Additional information
BrandL&T
SeriesDY125U
Ampere80A
Poles2 Pole
Breaking Capacity25 kA
Trip UnitThermal Magnetic
Voltage Rating240V AC