+ GST ₹1349.46
+ GST ₹1508.22
L&T DY250U1 MCCB 160-200A 3 Pole 415V 10kA Thermal Magnetic | CM98195OONO
₹7,657.02 Incl. of Taxes₹10,300.00 -37%Original price was: ₹10300.00.₹6,489.00Current price is: ₹6489.00.+ GST ₹1,168.02 (18%)
Total payable: ₹7657.02
Product image is for illustration purpose only – the photo shows a different rating of the same model.
L&T / Lauritz Knudsen DY250U1 MCCB, catalog no. CM98195OONO
160-200A adjustable overload, 3 Pole, 415V AC, 10kA breaking capacity (Icu = Ics)
Thermal-magnetic release (adjustable 0.8-1.0 x In) – spreader terminals included
GST invoice on every order | Same-day dispatch in Bengaluru for orders before 4 PM
Bulk and project rates on WhatsApp: +91 78160 62494
Note: the product photo is for illustration purpose only – it shows a different rating of the same model. The unit supplied is exactly the catalog number and rating on this page.
Looking for the L&T DY250U1 MCCB 160-200A 3 Pole? This is the genuine Lauritz Knudsen (formerly L&T Switchgear) DY series 250A frame moulded case circuit breaker, catalog number CM98195OONO, made for feeder and sub-distribution protection in commercial buildings, small industries and OEM panels. We stock it at our Chamrajpet shop in Bengaluru with a GST invoice on every order, same-day dispatch for orders placed before 4 PM (Monday to Saturday), and delivery across all of Bengaluru including outskirts. Free store pickup is available. For project and bulk rates, WhatsApp us on +91 78160 62494.
The DY250U1 covers the 125A to 250A band with an adjustable overload (thermal) setting of 0.8 to 1.0 x In – this unit is supplied in the 160-200A range, so you set the exact trip current on the dial within that window. Short-circuit protection is a fixed magnetic trip at 9 x In. Spreader terminals and phase barriers are included in the box, so terminating up to 120 mm² cable is straightforward with no separate accessory order.
With a 10 kA breaking capacity at 415V AC (Ics = 100% of Icu), the DY250U1 suits installations where the prospective fault level does not exceed 10 kA – typically sub-distribution feeders downstream of a larger incomer. For higher fault levels in the same frame, look at the DU250C (25 kA), DU250 (36 kA) or DU400N (50 kA) – we stock those too.
Practical panel-builder details: no load-line bias, so supply and load can connect to either side; clear ON / TRIP / OFF indication; suitable for isolation; conforms to IS/IEC 60947-2 and IEC 60947-2. Current rating is displayed on the mid-cover and the lockable shroud on the thermal knob prevents unauthorised changes to the overload setting.
Note on branding: L&T Switchgear is now Lauritz Knudsen Electrical & Automation (renamed in May 2024). Depending on stock, the unit may carry either the L&T or Lauritz Knudsen name. The catalog number, specifications and quality are identical.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | L&T / Lauritz Knudsen |
| Part Number / SKU | CM98195OONO |
| Category | MCCB (Moulded Case Circuit Breaker) |
| Series | DY250U1 |
| Current Rating (In) | 160-200 A (adjustable 0.8 – 1.0 x In) |
| Poles | 3 Pole |
| Breaking Capacity (Icu) | 10 kA (Icu = Ics) (@ 415V AC; 20 kA @ 240V AC) |
| Service Breaking Capacity (Ics) | 100% of Icu |
| Release Type | Thermal-Magnetic |
| Thermal (Overload) Setting | Adjustable, 0.8 – 1.0 x In (supplied in 160-200A range) |
| Magnetic (Short Circuit) Setting | Fixed, 9 x In (1800 A at the top of this range) |
| Rated Operational Voltage (Ue) | 415V AC, 50/60 Hz |
| Rated Insulation Voltage (Ui) | 800 V |
| Impulse Withstand Voltage (Uimp) | 8 kV |
| Utilization Category | A |
| Standard | IS/IEC 60947-2, IEC 60947-2, EN 60947-2 |
| Terminal Capacity | 120 mm² cable with lug (link ≤26 mm); spreader terminals included |
| Mechanical / Electrical Life | 10,000 / 1,000 operations |
| Dimensions (W x D x H) | 105 x 60 x 165 mm |
| Weight | 1.4 kg |
| IP Rating / Isolation | IP40 (front), suitable for isolation |
⚡ Key Features
- Genuine L&T / Lauritz Knudsen DY250U1 250A-frame MCCB – catalog no. CM98195OONO
- 160-200A adjustable overload, 3 Pole, 415V AC, 10 kA breaking capacity (Icu = Ics)
- Adjustable thermal setting 0.8 – 1.0 x In with lockable shroud; fixed magnetic trip 9 x In
- Spreader terminals and phase barriers included in the box
- No load-line bias – connect supply and load on either side
- Clear ON / TRIP / OFF indication; suitable for isolation
- GST invoice on every order; same-day dispatch in Bengaluru for orders before 4 PM
📄 Official Catalogue / Datasheet
Download the official L&T / Lauritz Knudsen DU/DY MCCB catalogue (covers DY250U1 technical data, trip curves, accessories and dimensions): DU/DY MCCB Catalogue (PDF, official)
❓ Frequently Asked Questions
Where can I use a 10 kA MCCB like the DY250U1?
Use it where the prospective short-circuit level at the installation point is 10 kA or less – typically sub-distribution feeders and panels downstream of a larger incomer breaker. Your panel designer or electrician works this out from the upstream transformer rating. If the fault level is higher, step up to the DU250C (25 kA), DU250 (36 kA) or DU400N (50 kA) in the same 250A/400A frames – we stock them.
Can I adjust the trip settings on this MCCB?
Yes, partially. The DY250U1 has an adjustable thermal (overload) dial from 0.8 to 1.0 x In – this unit covers the 160-200A range, so you can set the exact trip current within that window. The magnetic short-circuit trip is fixed at 9 x In. A lockable shroud over the thermal knob prevents unauthorised changes after setting.
Are spreader terminals included with this MCCB?
Yes. CM98195OONO is supplied with spreader terminals and phase barriers in the box, so terminating up to 120 mm2 cable needs no separate accessory order. The matching direct and extended rotary handles for door-mounted operation are in the Frequently Bought Together section below.
How fast can you deliver in Bengaluru?
Orders placed before 4 PM, Monday to Saturday, are dispatched the same day. We deliver across all of Bengaluru including outskirts like Sarjapur, Anekal and the airport side. Delivery charges are confirmed with you before dispatch. You can also pick up free from our Chamrajpet shop.
Do I get a GST invoice and what are the payment options?
Every order comes with a GST invoice suitable for ITC claims and project billing. Payment is prepaid through PhonePe – UPI, cards and netbanking are all accepted. For bulk quantities and project rates, WhatsApp us on +91 78160 62494.
| Brand | L&T |
|---|---|
| Series | DY250U1 |
| Ampere | 200A |
| Poles | 3 Pole |
| Breaking Capacity | 10 kA |
| Trip Unit | Thermal Magnetic |
| Voltage Rating | 415V AC |
Frequently Bought Together
L&T Rotary Handle DY250U1 Direct | CM98040OOOO
In stock
+ GST ₹224.53
L&T Rotary Handle DY250U1 Extended | CM98041OOOO
In stock
+ GST ₹288.04
Related products
L&T DY125U MCCB 100A 3 Pole 415V 10kA Thermal Magnetic | EM90983OOKO
In stock
+ GST ₹384.43
L&T DY125U MCCB 100A 4 Pole 415V 10kA Thermal Magnetic | EM90814OOKO
In stock
+ GST ₹459.27
L&T DY125U MCCB 80A 3 Pole 415V 10kA Thermal Magnetic | EM90983OOJO
In stock
+ GST ₹384.43
L&T DY125U MCCB 80A 4 Pole 415V 10kA Thermal Magnetic | EM90984OOJO
In stock
+ GST ₹530.71
L&T DY250U1 MCCB 160-200A 4 Pole 415V 10kA Thermal Magnetic | CM98196OONO
In stock
+ GST ₹1508.22
L&T DY250U1 MCCB 200-250A 3 Pole 415V 10kA Thermal Magnetic | CM98195OOPO
In stock
+ GST ₹1508.22
L&T DY250U1 MCCB 200-250A 4 Pole 415V 10kA Thermal Magnetic | CM98196OOPO
In stock
+ GST ₹2029.86
L&T Rotary Handle DY125U Extended | EM90970OOOO
In stock
+ GST ₹301.64

Legrand