+ GST ₹2455.20
+ GST ₹2620.80
L&T DN2-250D MCCB 200A (160-200A) 4 Pole 36kA Thermal Magnetic | CM92109OON1OG
₹20,579.20 Incl. of Taxes₹43,600.00 -60%Original price was: ₹43600.00.₹17,440.00Current price is: ₹17440.00.+ GST ₹3,139.20 (18%)
Total payable: ₹20579.20
Product image is for illustration purpose only – the photo shows a different rating of the same dsine family.
L&T / Lauritz Knudsen dsine DN2-250D MCCB, catalog no. CM92109OON1OG
200A (160-200A), 4 Pole, 36kA @ 415V AC breaking capacity (Ics = 100% of Icu)
Adjustable thermal 0.8-1.0 x In, adjustable magnetic 6-10 x In
GST invoice on every order | Same-day dispatch in Bengaluru for orders before 4 PM
Bulk and project rates on WhatsApp: +91 78160 62494
Note: the product photo is for illustration purpose only – it shows a different rating of the same dsine family. The unit supplied is exactly the catalog number and rating on this page.
Looking for the L&T DN2-250D MCCB 200A 4 Pole? This is the genuine Lauritz Knudsen (formerly L&T Switchgear) dsine DN series moulded case circuit breaker, catalog number CM92109OON1OG, made for feeder, incomer and sub-distribution protection in commercial buildings, industries and OEM panels. We stock it at our Chamrajpet shop in Bengaluru with a GST invoice on every order, same-day dispatch for orders placed before 4 PM (Monday to Saturday), and delivery across all of Bengaluru including outskirts. Free store pickup is available. For project and bulk rates, WhatsApp us on +91 78160 62494.
Breaking capacity is 36 kA at 415V AC (Ics = 100% of Icu). The dsine DN range gives you a thermal-magnetic release with an adjustable thermal (overload) setting from 0.8 to 1.0 times In – this unit covers 200A (160-200A) – and an adjustable magnetic short-circuit setting from 6 to 10 times In. That adjustability lets you trim the protection to the actual load and cable size during commissioning.
Spreader terminals are not included with this catalog number – if your panel needs them for cable termination, add the matching DN2-250 4 pole spreader link set and, for panel-door operation, the direct or extended rotary handle from the Frequently Bought Together section below. One set covers one MCCB. Phase barriers are supplied with the unit.
Practical panel-builder details: no load-line bias, so supply and load can connect to either side; clear ON / TRIP / OFF indication; suitable for isolation; conforms to IS/IEC 60947-2.
Note on branding: L&T Switchgear is now Lauritz Knudsen Electrical & Automation (renamed in May 2024). Depending on stock, the unit may carry either the L&T or Lauritz Knudsen name. The catalog number, specifications and quality are identical.
📋 Technical Specifications
| Parameter | Value |
|---|---|
| Brand | L&T / Lauritz Knudsen |
| Part Number / SKU | CM92109OON1OG |
| Category | MCCB (Moulded Case Circuit Breaker) |
| Series | dsine DN2-250D |
| Current Rating (In) | 200 A (adjustable range 200A (160-200A)) |
| Poles | 4 Pole |
| Breaking Capacity (Icu) | 36 kA @ 415V AC (Icu @ 415V AC) |
| Service Breaking Capacity (Ics) | 100% of Icu |
| Release Type | Thermal-Magnetic (adjustable thermal, adjustable magnetic) |
| Thermal (Overload) Setting | Adjustable 0.8 – 1.0 x In (this unit settable 200A (160-200A)) |
| Magnetic (Short Circuit) Setting | Adjustable 6 – 10 x In (600 – 2000 A for this 200A unit) |
| Rated Operational Voltage (Ue) | 690V AC, 50/60 Hz |
| Rated Insulation Voltage (Ui) | 800 V |
| Impulse Withstand Voltage (Uimp) | 8 kV |
| Utilization Category | A |
| Standard | IS/IEC 60947-2 |
| Making Capacity (Icm) | 75.6 kA |
| Mechanical / Electrical Life | 25,000 / 10,000 operations |
| Dimensions (W x D x H) | 140 x 96 x 179 mm |
| Weight | 3.3 kg |
| IP Rating / Isolation | IP40 (front), suitable for isolation |
⚡ Key Features
- Genuine L&T / Lauritz Knudsen dsine DN2-250D MCCB – catalog no. CM92109OON1OG
- 200A, 4 Pole, 36 kA breaking capacity at 415V AC (Ics = 100% of Icu)
- Adjustable thermal 0.8 – 1.0 x In; adjustable magnetic 6 – 10 x In
- Phase barriers included; spreader terminals and rotary handles available separately below
- No load-line bias – connect supply and load on either side
- Clear ON / TRIP / OFF indication; suitable for isolation
- GST invoice on every order; same-day dispatch in Bengaluru for orders before 4 PM
📄 Official Catalogue / Datasheet
Download the official L&T / Lauritz Knudsen dsine DN MCCB catalogue (covers DN2-250D technical data, trip curves, accessories and dimensions): dsine DN MCCB Catalogue (PDF, official)
❓ Frequently Asked Questions
Where can I use a 36 kA MCCB like the DN2-250D?
Use it where the prospective short-circuit level at the installation point is 36 kA or less – typically incomers and feeders in commercial and industrial distribution boards. Your panel designer or electrician works this out from the upstream transformer rating. The dsine DN range covers 25 kA, 36 kA and 50 kA variants – if you need a different fault level, ask us on WhatsApp and we will point you to the right catalog number.
Can I adjust the trip settings on this MCCB?
Yes – the DN2-250D has an adjustable thermal (overload) dial from 0.8 to 1.0 times In (this 200A unit covers 200A (160-200A)) and an adjustable magnetic short-circuit setting from 6 to 10 times In. If you need earth-fault protection or metering, look at the DN range with MTX microprocessor releases.
Are spreader terminals included with this MCCB?
No – CM92109OON1OG is the without-spreader variant, which keeps the price lower. If your panel needs spreader terminals for 4 pole cable termination, add the matching DN2-250 4 pole spreader link set from the Frequently Bought Together section below – one set covers one MCCB.
How fast can you deliver in Bengaluru?
Orders placed before 4 PM, Monday to Saturday, are dispatched the same day. We deliver across all of Bengaluru including outskirts like Sarjapur, Anekal and the airport side. Delivery charges are confirmed with you before dispatch. You can also pick up free from our Chamrajpet shop.
Do I get a GST invoice and what are the payment options?
Every order comes with a GST invoice suitable for ITC claims and project billing. Payment is prepaid through PhonePe – UPI, cards and netbanking are all accepted. For bulk quantities and project rates, WhatsApp us on +91 78160 62494.
| Brand | L&T |
|---|---|
| Series | DN2-250D |
| Ampere | 200A |
| Poles | 4 Pole |
| Breaking Capacity | 36 kA |
| Trip Unit | Thermal Magnetic |
| Voltage Rating | 415V AC |
Frequently Bought Together
L&T Rotary Handle DN2 Direct | CM99829OOOO
In stock
+ GST ₹146.88
L&T Rotary Handle DN2 Extended | CM99830OOOO
In stock
+ GST ₹221.04
L&T Spreader Link DY250U1 4 Pole | CM92007OOOO
In stock
+ GST ₹392.36
Related products
L&T DY125U MCCB 125A 3 Pole 415V 10kA Thermal Magnetic | EM90983OOLO
In stock
+ GST ₹564.73
L&T DY125U MCCB 80A 2 Pole 240V 25kA Thermal Magnetic | EM90982OOJO
In stock
+ GST ₹319.79
L&T DY125U MCCB 80A 3 Pole 415V 10kA Thermal Magnetic | EM90813OOJO
In stock
+ GST ₹341.33
L&T DY250U1 MCCB 125-160A 4 Pole 415V 10kA Thermal Magnetic | CM98196OOMO
In stock
+ GST ₹1349.46
L&T Rotary Handle DY250U1 Extended | CM98041OOOO
In stock
+ GST ₹288.04
L&T Spreader Link DY125U 2 Pole | CM97785OOO2
In stock
+ GST ₹45.36
L&T Spreader Link DY125U 3 Pole | CM97785OOOO
In stock
+ GST ₹72.58
L&T Spreader Link DY125U 4 Pole | CM97921OOOO
In stock
+ GST ₹113.40

Legrand